AFM 7.10.1 GENERAL – Distribution
Distribution
Electrical power is distributed via the hot battery bus, the battery bus 1, the battery bus 2, the ECU-bus, the main bus, the essential bus and the avionic bus.
Hot Battery Bus:
The hot battery bus is directly connected to the main-battery installed in the relay junction box and cannot be disconnected from the main battery. The hot battery bus provides power to the accessory power plug and ELT which are protected by their own fuses.
Battery Bus 1:
The battery bus 1 is connected to the main-battery via the battery-relay which can be controlled by the ELECTRIC MASTER key switch. The battery bus 1 provides power to the battery bus 2 and heavy duty power to the starter.
The battery bus 1 is also connected to the power input line of the external power plug.
Battery Bus 2:
The battery bus 2 is connected to the battery bus 1 via a 100 A fuse and provides power to the ECU bus via a 80 A fuse. It aso provides power to the main bus via the power relay which can be controlled by the ELECTRIC MASTER key switch and the ESSENTIAL BUS switch. The ELECTRIC MASTER key switch must be set to ON and the ESSENTIAL BUS switch must be set to OFF to connect the battery bus to the main bus.
ECU Bus:
The ECU bus is connected to the battery bus 2 via a 80 A fuse and provides power for the ECU A and ECU B and their fuel pumps. it is also connected to the power output line of the alternator via a 100 A fuse. It also provides power for charging the ECU backup-battery. The ENGINE MASTER switch must be set to ON to activate the ECU A and ECU B to the ECU bus.
Main bus:
The main bus it connected to the battery bus via the power-relay. It provides power to the consumers directly connected to the main bus and the avionic bus via the avionic master-relay. The AVIONIC MASTER switch must be set to ON to connect the main bus to the avionic bus. Under normal operating conditions the main bus is also connected to the essential bus via the essential tie-relay. In the event of an alternator failure the pilot must switch ON the ESSENTIAL BUS switch (refer to Section 3.4 – FAILURES IN THE ELECTRICAL SYSTEM). This separates the main bus from the battery bus and the essential bus and the equipment connected to the main bus no longer has power.
Essential Bus:
Under normal operating conditions the essential bus is connected to the main bus via the essential tie-relay. The essential bus provides power to the consumers connected to the essential bus. The AVIONIC MASTER switch must be set to ON to connect the essential bus to the avionic bus. In the event of an alternator failure the pilot must switch ON the ESSENTIAL BUS switch (refer to Section 3.4 – FAILURES OF THE ELECTRICAL SYSTEM). This separates the essential bus from the main bus. The essential bus is then connected to the battery bus 2 which provides battery power for a limited time to the equipment essential for safe flight and landing.
분배
전력은 핫 배터리 버스, 배터리 버스 1, 배터리 버스 2, ECU 버스, essential 버스, avionic 버스를 통해 분배된다.
핫 배터리 버스:
핫 배터리 버스는 relay junction box에 장착된 메인 배터리에 직접 연결되어 있고 메인 배터리와 분리될 수 없도록 되어있다. 핫 배터리 버스는 각각 퓨즈에 의해 보호되는 Accessory 전원 플러그와 ELT(Emergency Location Transponder)에 전력을 공급한다.
배터리 버스 1:
배터리 버스 1은 일렉트릭 마스터키에 의해 조작되는 배터리 릴레이를 통해 메인 배터리에 연결되어 있다. 배터리 버스 1은 배터리 버스 2에 전력을 공급해주고 starter에 강한 전력을 공급한다.
배터리 버스 1은 외부 전원 플러그 선에도 연결되어 있다.
배터리 버스 2:
배터리 버스 2는 배터리 버스 1으로부터 100암페어 퓨즈를 거쳐 연결되어 있으며 ECU 버스에 80암페어 퓨즈를 거쳐 전력을 공급한다. 또한 일렉트릭 마스터 키와 ESSENTIAL 버스 스위치를 통해 조작될 수 있는 파워 릴레이를 통해 메인 버스에 전력을 공급한다. 배터리 버스를 메인 버스에 연결시키기 위해서는 일렉트릭 마스터 키 스위치가 ON에, 그리고 ESSENTIAL 버스 스위치는 OFF에 위치해 있어야만 한다.
ECU 버스:
ECU 버스는 배터리 버스 2 로부터 80암페어 퓨즈를 거쳐 연결되어 있으며 ECU A 와 ECU B, 그리고 각각의 퓨엘 펌프에 전력을 공급한다. 또한 100 암페어 퓨즈를 거쳐 발전기 전기 출력 선에 연결되어 있다. ECU 버스는 ECU 백업 배터리를 충전시키기도 한다. ECU A, ECU B 를 ECU 버스에 연결하여 동작시키려면 엔진 마스터 스위치가 ON에 위치해야만 한다.
메인 버스:
메인 버스는 파워 릴레이를 통해 배터리 버스에 연결되어 있다. avionic 마스터 릴레이를 통해 avionic 버스와 메인 버스에 직접 연결된 전력 소비 시스템들에 전력을 제공한다. avionic 버스를 메인 버스에 연결시키리면 AVIONIC 마스터 스위치를 ON에 위치하도록 해야한다. 정상적인 상황에서 메인버스는 essential tie-릴레이를 통해 essential 버스에 연결되어 있다. 발전기가 고장난 상황에서 조종사는 ESSENTIAL 버스의 스위치를 ON 해야만 한다(Section 3.4 – FAILURES IN THE ELECTRICAL SYSTEM 참조). 이는 메인버스를 배터리버스와 essential 버스로부터 분리시키고 메인버스에 연결된 장비들은 더 이상 전력을 공급받을 수 없게 된다.
Essential 버스:
정상적인 상황에서 essential 버스는 essential tie-릴레이를 통해 메인 버스에 연결되어 있다. essential 버스는 그에 연결된 전력 소비 시스템에게 전력을 제공한다. essential 버스를 avionic 버스에 연결시키려면 AVIONIC 마스터 스위치를 ON에 두어야 한다. 발전기가 고장난 상황에서 조종사는 ESSENTIAL 버스의 스위치를 ON 해야만 한다(Section 3.4 – FAILURES IN THE ELECTRICAL SYSTEM 참조). 이는 메인 버스로부터 essential 버스를 분리시킨다. 그 후 essential 버스는 배터리 버스 2에 연결하여 한정된 시간동안 중요한 장비들에게 전력을 공급함으로써 안전한 비행과 착륙을 할 수 있도록 해준다.