Daily

AFM 7.10.1 GENERAL – Consumers

한국어로 읽기 →

Consumers

The individual consumers (e.g. radio, electrical fuel transfer pump, position lights, etc.) are connected to the appropriate bus via automatic circuit breakers.

Designations and abbreviations used to identify the circuit breakers are explained in Section 1.5 – DEFINITIONS AND ABBREVIATIONS.

Voltmeter

The voltmeter shows the voltage of the essential bus. Under normal operating conditions the alternator voltage is shown, otherwise it is the voltage of the main battery.

Ammeter

The ammeter displays the intensity of current /which is supplied to the electrical system by the alternator, including the current for battery charging.

Landing and Taxi Lights

Landing and taxi lights are built into the left wing, and are each operated by means of a switch (LANDING, TAXI) on the row of switches on the instrument panel.

Position and Strobe Lights

Combined position and strobe lights (anti collision lights) are installed on both wing tips. Each system is operated by a switch (POSITION, STROBE) on the row of switched on the instrument panel.

Flood Light

A two-dimensional light emitter is mounted above the instrument panel. It illuminates the instrument panel as well as all levers, switches, etc. With a rotary button (FLOOD) in the left-hand section of the instrument panel the flood light is switched on and its brightness is adjusted.

Instrument Lighting

With a rotary button (INSTRUMENT) in the left-hand section of the instrument panel the internal lighting of the instruments is switched on and its brightness is adjusted.

Pitot Heating

The Pitot probe, which provides measurement for the Pitot-static system, is electrically heated. The heating is activated with a switch (PITOT) on the row of switches on the instrument panel. The temperature is automatically kept constant by means of a thermal switch on the Pitot probe, and as an additional safety measure a thermal fuse is built in. If this thermal fuse is activated, the Pitot heating can no longer be switched on. PITOT FAIL on the G1000 (if installed) or PITOT on the White Wire annunciator panel (if installed) will be displayed, if the thermal fuse or the thermal switch is activated and the PITOT HT is set to ON. The PITOT HT OFF indication on the G1000 (if installed) is on if the Pitot heating is switched off.

Power Consumer Systems

Each of the power-consuming systems (e.g. radio, fuel transfer pump, position lights, etc.) is connected to its corresponding bus via automatic circuit breakers.

The designations and abbreviations used for the circuit breakers are explained in Section 1.5 – DEFINITIONS AND ABBREVIATIONS.

Voltmeter

The voltmeter shows the voltage of the essential bus. Under normal conditions it shows the alternator voltage, or else the voltage of the main battery.

Ammeter

The ammeter displays the intensity of the current supplied to the electrical system by the alternator, and of the current for charging the battery.

Landing and Taxi Lights

The landing and taxi lights are fitted in the left wing and are each operated via the LANDING and TAXI switches on the instrument panel.

Position and Strobe (Flashing) Lights

The combined position and strobe lights (anti-collision lights) are installed on both wing tips. Each system is operated by the POSITION and STROBE switches on the instrument panel.

Interior Light

A two-dimensional, flat-surfaced light is mounted above the instrument panel. It illuminates the instrument panel, and likewise all the levers, switches, etc. There is a rotary FLOOD button in the left-hand section of the instrument panel; after turning it ON, the brightness can be adjusted as needed.

Instrument Lights

There is a rotary INSTRUMENT button in the left-hand section of the instrument panel, which illuminates the inside of the instruments. After turning the switch ON, the brightness can be adjusted as needed.

Pitot Heating

The pitot probe, which provides measurements for the pitot-static system, is electrically heated. It can be heated by operating the PITOT switch located on the instrument panel. The temperature is maintained automatically by the pitot probe, and for safety a thermal fuse is additionally built in. If the thermal fuse is activated, the pitot heating switch must not be left ON. If PITOT FAIL appears on the G1000 (if installed) or PITOT appears on the White Wire annunciator panel (if installed), it means the thermal fuse or thermal switch is operating while the pitot heating switch is ON. When the pitot heating switch is turned OFF, PITOT HT OFF is displayed on the G1000 (if installed).