Electrical power is distributed via the hot battery bus, the battery bus 1, the battery bus 2, the ECU-bus, the main bus, the essential bus and the avionic bus.
Hot Battery Bus:
The hot battery bus is directly connected to the main-battery installed in the relay junction box and cannot be disconnected from the main battery. The hot battery bus provides power to the accessory power plug and ELT which are protected by their own fuses.
Battery Bus 1:
The battery bus 1 is connected to the main-battery via the battery-relay which can be controlled by the ELECTRIC MASTER key switch. The battery bus 1 provides power to the battery bus 2 and heavy duty power to the starter.
The battery bus 1 is also connected to the power input line of the external power plug.
Battery Bus 2:
The battery bus 2 is connected to the battery bus 1 via a 100 A fuse and provides power to the ECU bus via a 80 A fuse. It aso provides power to the main bus via the power relay which can be controlled by the ELECTRIC MASTER key switch and the ESSENTIAL BUS switch. The ELECTRIC MASTER key switch must be set to ON and the ESSENTIAL BUS switch must be set to OFF to connect the battery bus to the main bus.
ECU Bus:
The ECU bus is connected to the battery bus 2 via a 80 A fuse and provides power for the ECU A and ECU B and their fuel pumps. it is also connected to the power output line of the alternator via a 100 A fuse. It also provides power for charging the ECU backup-battery. The ENGINE MASTER switch must be set to ON to activate the ECU A and ECU B to the ECU bus.
Main bus:
The main bus it connected to the battery bus via the power-relay. It provides power to the consumers directly connected to the main bus and the avionic bus via the avionic master-relay. The AVIONIC MASTER switch must be set to ON to connect the main bus to the avionic bus. Under normal operating conditions the main bus is also connected to the essential bus via the essential tie-relay. In the event of an alternator failure the pilot must switch ON the ESSENTIAL BUS switch (refer to Section 3.4 – FAILURES IN THE ELECTRICAL SYSTEM). This separates the main bus from the battery bus and the essential bus and the equipment connected to the main bus no longer has power.
Essential Bus:
Under normal operating conditions the essential bus is connected to the main bus via the essential tie-relay. The essential bus provides power to the consumers connected to the essential bus. The AVIONIC MASTER switch must be set to ON to connect the essential bus to the avionic bus. In the event of an alternator failure the pilot must switch ON the ESSENTIAL BUS switch (refer to Section 3.4 – FAILURES OF THE ELECTRICAL SYSTEM). This separates the essential bus from the main bus. The essential bus is then connected to the battery bus 2 which provides battery power for a limited time to the equipment essential for safe flight and landing.
Distribution
Electrical power is distributed via the hot battery bus, battery bus 1, battery bus 2, the ECU bus, the essential bus and the avionic bus.
Hot Battery Bus:
The hot battery bus is directly connected to the main battery installed in the relay junction box and is designed so that it cannot be disconnected from the main battery. The hot battery bus supplies power to the accessory power plug and the ELT (Emergency Location Transponder), each of which is protected by its own fuse.
Battery Bus 1:
Battery bus 1 is connected to the main battery via the battery relay, which is operated by the electric master key. Battery bus 1 supplies power to battery bus 2 and heavy-duty power to the starter.
Battery bus 1 is also connected to the external power plug line.
Battery Bus 2:
Battery bus 2 is connected from battery bus 1 via a 100-ampere fuse, and supplies power to the ECU bus via an 80-ampere fuse. It also supplies power to the main bus via the power relay, which can be operated with the electric master key and the ESSENTIAL bus switch. To connect the battery bus to the main bus, the electric master key switch must be in the ON position and the ESSENTIAL bus switch must be in the OFF position.
ECU Bus:
The ECU bus is connected from battery bus 2 via an 80-ampere fuse and supplies power to ECU A and ECU B and their respective fuel pumps. It is also connected to the alternator’s electrical output line via a 100-ampere fuse. The ECU bus also charges the ECU backup battery. To connect ECU A and ECU B to the ECU bus and operate them, the engine master switch must be in the ON position.
Main Bus:
The main bus is connected to the battery bus via the power relay. It supplies power to the avionic bus via the avionic master relay, and to the power-consuming systems connected directly to the main bus. To connect the avionic bus to the main bus, the AVIONIC master switch must be in the ON position. Under normal conditions the main bus is connected to the essential bus via the essential tie relay. If the alternator fails, the pilot must switch the ESSENTIAL bus switch ON (refer to Section 3.4 – FAILURES IN THE ELECTRICAL SYSTEM). This separates the main bus from the battery bus and the essential bus, and the equipment connected to the main bus can no longer receive power.
Essential Bus:
Under normal conditions the essential bus is connected to the main bus via the essential tie relay. The essential bus supplies power to the power-consuming systems connected to it. To connect the essential bus to the avionic bus, the AVIONIC master switch must be in the ON position. If the alternator fails, the pilot must switch the ESSENTIAL bus switch ON (refer to Section 3.4 – FAILURES IN THE ELECTRICAL SYSTEM). This separates the essential bus from the main bus. The essential bus is then connected to battery bus 2, which supplies power to the critical equipment for a limited time so that a safe flight and landing can be made.