Main battery power is stored in a 24 V, 13.6 Ah lead-acid battery mounted behind the baggage compartment frame. The main battery is connected to the battery bus via the battery-relay which is installed in the relay junction box behind the baggage compartment frame.

The battery relay is controlled with the ELECTRIC MASTER key switch which is located in the center of the instrument panel.

In addition, two 12 V, 7.2 Ah sealed-lead-acid batteries (ECU backup-batteries) are installed behind the first ring frame as a further source of electrical power for the Engine Control Unit (ECU B only).

Under normal operating conditions the ECU backup batteries are charged by the ECU bus. In the event of an alternator failure and a depleted main battery the ECU backup batteries automatically supply electrical power to ECU B via a 32 A fuse. This prevents the engine from stopping in the unlikely event of an alternator failure and a totally discharged main battery.

In addition, a non-rechargeable dry battery is installed in the IFR model as a further source of power for the attitude gyro (artificial horizon) and the flood light. When the EMERGENCY switch is set to ON, these two systems are supplied with power for 1 hour, independent of all other electrical consumers. During each 100 hour inspection, this battery is checked for proper functioning, Every 2 years or after use (broken seal on the switch) the battery pack must be replaced.

Storage

The main battery is a 24-volt, 13.6-ampere lead-acid battery located behind the baggage compartment. The main battery is connected to the battery bus through the battery relay located in the relay junction box behind the baggage compartment.

The battery relay is operated by the Electric Master key switch located in the center of the instrument panel.

Also, as an additional power source for the ECU, two 12-volt, 7.2-ampere sealed lead-acid batteries (ECU backup batteries) are mounted behind the first ring frame. (Applies to ECU B only.)

Under normal operation the ECU backup batteries are charged by the ECU bus. If the alternator fails or the main battery is drained, the ECU backup batteries automatically supply power to ECU B through a 32A fuse. This keeps the engine from stopping in unexpected situations such as an alternator failure or a drained main battery.

Also, a non-rechargeable dry battery is installed inside the IFR model to supply power to the attitude gyro (artificial horizon) and the cabin light in situations like the above. When the EMERGENCY switch is set to ON, it supplies power to only these two systems for 1 hour, separately from the other systems that use power. During the 100-hour inspection this battery must be checked to make sure it works properly, and it must be replaced every 2 years, or if it has been used and the seal on the switch is broken.